Emission Factor Details

SCC 10100306
  Level 1 External Combustion Boilers
  Level 2 Electric Generation
  Level 3 Lignite
  Level 4 Spreader Stoker
POLLUTANT Total non-methane organic compounds (TNMOC) NEI CAS
  Primary Control       CHEMICAL REDUCTION

Emission Factor 3.000E-2 Lb per Ton Lignite Burned
Quality C    Emissions Factors Applicability

References EPA. September, 1998. Section 1.7, Lignite Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S.Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.7
Formula
Notes Emission factors were derived from bituminous coal data in the absence of lignite data assuming emissions are proportional to coal heating value. TNMOC are expressed as C2 to C16 alkane equivalents. Because of limited data, the effects of firing configuration on TNMOC emission factors could not be distinguished. As a result, all data were averaged collectively to develop a single average emission factor for pulverized coal, cyclones, spreaders, and overfeed stokers. Normal operating conditions; values 1 or 2 orders of magnitude higher can occur when combustion is not complete.