Emission Factor Details
SCC | 10100301 | ||
Level 1 | External Combustion Boilers | ||
Level 2 | Electric Generation | ||
Level 3 | Lignite | ||
Level 4 | Pulverized Coal: Dry Bottom, Wall Fired | ||
POLLUTANT | PM, condensable | NEI PM-CON | CAS |
Primary Control
ROTOCLONE |
|||
Emission Factor | Formula Lb per Ton Lignite Burned | ||
Quality | C Emissions Factors Applicability | ||
References | EPA. September, 1998. Section 1.7, Lignite Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S.Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina. | ||
AP 42 Section | Chapter 1 Section 1.7 | ||
Formula | (1E-1*S-3E-2)*16 | ||
Notes | Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton of lignite coal, multiply by 16 MMBtu/ton. 80% of the condensable PM is inorganic; 20% of the condensable PM is organic. |