Emission Factor Details

SCC 10300903
  Level 1 External Combustion Boilers
  Level 2 Commercial/Institutional
  Level 3 Wood/Bark Waste
  Level 4 Wood-fired Boiler - Wet Wood (>=20% moisture)
POLLUTANT PM, filterable NEI PM-FIL CAS
  Primary Control       DUCT SORBENT INJECTION

Emission Factor 1.000E-1 Lb per MMBtu Heat Input
Quality C    Emissions Factors Applicability

References EPA. September, 2003. Section 1.6, Wood Residue Combustion In Boilers. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.6
Formula
Notes To convert the emission factor from Lb/MMBtu to Lb/ton, multiply the emission factor by (HHV * 2000) where ""HHV"" is the higher heating value of the fuel (MMBtu/lb).