Emission Factor Details

SCC 10300902
  Level 1 External Combustion Boilers
  Level 2 Commercial/Institutional
  Level 3 Wood/Bark Waste
  Level 4 Wood/Bark-fired Boiler
POLLUTANT PM, filterable NEI PM-FIL CAS
  Primary Control       FABRIC FILTER - LOW TEMPERATURE , I.E. T<180F

Emission Factor 6.000E0 Lb per Ton Wood/Bark Burned Revoked on 02/01/1998
Quality C    Emissions Factors Applicability

References EPA. 1995. Section 1.6, Wood Waste Combustion in Boilers. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.6
Formula
Notes Emission factors are based on wet, as-fired wood waste with average properties of 50 weight percent moisture and 2,500 kcal/kg (4,500 Btu/lb) higher heating value.