Emission Factor Details

SCC 10300901
  Level 1 External Combustion Boilers
  Level 2 Commercial/Institutional
  Level 3 Wood/Bark Waste
  Level 4 Bark-fired Boiler
POLLUTANT 2,3,7,8-Tetrachlorodibenzo-p-dioxin NEI 1746016 CAS 1746-01-6
  Primary Control       CHEMICAL REDUCTION

Emission Factor 3.600E-11 Lb per Ton Bark Burned Revoked on 02/01/1998
Quality D    Emissions Factors Applicability

References EPA. 1995. Section 1.6, Wood Waste Combustion in Boilers. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.6
Formula
Notes Emission factors are based on wet, as-fired wood waste with average properties of 50 weight percent moisture and 4500 Btu/lb higher heating value.