Science Inventory

THE BAFFLED FLASK TEST FOR DISPERSANT EFFECTIVENESS: A ROUND ROBIN EVALUATION OF REPRODUCIBILITY AND REPEATABILITY

Citation:

Venosa*, A D., D. King, AND G. A. Sorial. THE BAFFLED FLASK TEST FOR DISPERSANT EFFECTIVENESS: A ROUND ROBIN EVALUATION OF REPRODUCIBILITY AND REPEATABILITY. Champ, M.A. (ed.), SPILL SCIENCE AND TECHNOLOGY BULLETIN. Elsevier Science Ltd, London, Uk, 7(5-6):299-308, (2002).

Description:

After two previous investigations demonstrated that the Baffled Flask Test (BFT) was an effective and reproducible method for screening the effectiveness of dispersant products in the laboratory, the USEPA decided that before the new protocol cold be considered for replacement of the Swirling Flask Test (SFT), it would have to be subjected to an interlaboratory round robin investigation. This paper describes how the round robin evaluation was carried out and presents repeatability and reproducibility calculations that demonstrate the superiority of the new method over previous methods. Probabilities for passing various threshold levels of effectiveness values were computed, and the results will be used by the Agency to develop final pass-fail decision rules for dispersant manufacturers wishing to have their products listed on the National Contingency Plan Product Schedule.

Record Details:

Record Type:DOCUMENT( JOURNAL/ PEER REVIEWED JOURNAL)
Product Published Date:12/01/2002
Record Last Revised:12/22/2005
Record ID: 75335