Science Inventory

DETERMINATION OF HETEROGENEOUS ELECTRON TRANSFER RATE CONSTANTS AT MICROFABRICATED IRIDIUM ELECTRODES. (R825511C022)

Citation:

Feeney, R. AND S. P. Kounaves. DETERMINATION OF HETEROGENEOUS ELECTRON TRANSFER RATE CONSTANTS AT MICROFABRICATED IRIDIUM ELECTRODES. (R825511C022). ELECTROANALYSIS. American Chemical Society, Washington, DC, 1:453-458, (1999).

Description:

There has been an increasing use of both solid metal and microfabricated iridium electrodes as substrates for various types of electroanalysis. However, investigations to determine heterogeneous electron transfer rate constants on iridium, especially at an electron beam evaporated or dc magnetron sputtered surface, have not previously been performed. This paper compares the results of these microfabricated surfaces using ultramicroelectrode arrays and steady-state currents. Even though the dc magnetron sputtered iridium surface demonstrated a slightly more reversible electrochemical behavior than the electron beam evaporated surface, overall the microfabricated microelectrodes and ring electrode indicated similar reversibility to the polished metallic iridium disk electrode.

Author Keywords: Iridium; Rate constant; Steady-state current; Ferricyanide; Microfabrication

Record Details:

Record Type:DOCUMENT( JOURNAL/ PEER REVIEWED JOURNAL)
Product Published Date:01/01/1999
Record Last Revised:12/22/2005
Record ID: 70867