Science Inventory

DETERMINATION OF PERCHLORATE AT TRACE LEVELS IN DRINKING WATER BY ION-PAIR EXTRACTION WITH ELECTROSPRAY IONIZATION MASS SPECTROMETRY.

Citation:

Magnuson*, M L., E T. Urbansky*, AND C A. Kelty*. DETERMINATION OF PERCHLORATE AT TRACE LEVELS IN DRINKING WATER BY ION-PAIR EXTRACTION WITH ELECTROSPRAY IONIZATION MASS SPECTROMETRY. Analytical Chemistry. American Chemical Society, Washington, DC, 72(1):25-29, (2000).

Description:

Perchlorate has been added to the U.S. Environmental Protection Agency,s Drinking Water Contaminant Candidate List (CCL). The present work describes the analysis of perchlorate in water by liquid-liquid extraction followed by flow injection electrospray mass spectrometry (ESI/MS). Cationic surfactants, mostly alkyltrimethyl-ammonium salts, are used to ion-pair aqueous perchlorate, forming extractable ion pairs. The cationic surfactant associates with the perchlorate ion to form a complex detectable by ESI/MS. The selectivity of the extraction and the mass spectrometric detection increases confidence in the identification of perchlorate. The method detection limit for perchlorate based on 3.14Fn-1 of seven replicate injections was 100 ng L-1 (parts per trillion). Standard addition was used to quantitate perchlorate in a drinking water sample from a contaminated source, and the concentration determined agreed within experimental error with the concentration determined by ion chromatography.

Record Details:

Record Type:DOCUMENT( JOURNAL/ PEER REVIEWED JOURNAL)
Product Published Date:01/01/2000
Record Last Revised:12/22/2005
Record ID: 64449