Science Inventory

INTEGRITY OF VOA-VIAL SEALS

Citation:

Schumacher, B A., M. M. Minnich, J. H. Zimmerman, AND J. Blasdell. INTEGRITY OF VOA-VIAL SEALS. U.S. Environmental Protection Agency, Washington, DC, EPA/600/R-00/066 (NTIS PB2001-101547), 2000.

Impact/Purpose:

The overall objective of this task is to provide the Agency with improved state-of-the-science guidance, strategies, and techniques to more accurately and effectively collect environmental samples. Under this umbrella objective, research is being conducted to: (a) reduce/minimize the loss of VOCs during sample collection, handling, and preservation, (b) collect undisturbed surface sediments so that the effects of recent depositional events (e.g., flooding or dredging) can clearly be delineated as to their influence on the contamination concentrations present downstream (or where the sediments are deposited), and (c) to determine an effective method to effectively and efficiently separate asbestos in soils from the rest of the soil matrix while maintaining the integrity (i.e, no fiber size reduction) of the asbestos fibers.

Description:

Preservation of soil samples for the analysis of volatile organic compounds (VOCs) requires both the inhibition of VOC degradation and the restriction of vapor movement in or out of the sample container. Clear, 40,mL glass VOA vials manufactured by the four major U.S. glass manufacturers were tested for seal integrity. Visual inspection revealed a variety of imperfections ranging from small indentations, bumps, and scratches on vial threads or lips, through obvious defects, such as large indentations or grooves in the vial lips and chipped or broken glass. The aluminum plate vacuum test proved to be unreliable in identifying potentially leaky vials. The septa-seal vacuum test was conducted twice on the 80 selected vials.

Mean VOC concentrations after 14 days storage generally were within +- 20% of the known concentration with a majority of the concentrations within +- 15% of their known values. There were no statistically significant differences in VOC concentrations between vials in the potentially leaky and control group for any of the manufacturers. Only 1 vial lost VOCs and that was due to a large chip in the vial's lip and neck. These findings indicate that the silicone septa are flexible enough to overcome most vial imperfections and form a complete seal against VOC loss. A careful inspection of the VOA vials prior to use to remove any vials with large and obvious imperfections should be sufficient to screen out vials that are subject to VOC losses.

Record Details:

Record Type:DOCUMENT( PUBLISHED REPORT/ REPORT)
Product Published Date:09/15/2000
Record Last Revised:12/22/2005
Record ID: 63172