Science Inventory

FIELD TESTS OF INDUSTRIAL STOKER COAL-FIRED BOILERS FOR EMISSIONS CONTROL AND EFFICIENCY IMPROVEMENT - SITE D

Citation:

Gabrielson, J., P. Langsjoen, AND T. Kosvic. FIELD TESTS OF INDUSTRIAL STOKER COAL-FIRED BOILERS FOR EMISSIONS CONTROL AND EFFICIENCY IMPROVEMENT - SITE D. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/7-79/237A.

Description:

The report gives results of field measurements made on a 90,000 lb/hr vibrating-grate-stoker boiler. The effect of various parameters on boiler emissions and efficiency was studied. Parameters included overfire air, excess air, boiler load, and fuel properties. Measurements included gaseous emissions, particulate emissions, particle size distribution of the flyash, and combustible content of the ash. Gaseous emissions measured were O2, CO2, CO, NO, SO2, and SO3 in the flue gas. Sample locations included the boiler outlet and the multiclone dust collecter outlet. In addition to test results and observations, the report describes the facility tested, coals fired, test equipment, and procedures.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 51402