DISPERSION OF ROOF-TOP EMISSIONS FROM ISOLATED BUILDINGS. A WIND TUNNEL STUDY

Citation:

Thompson, Roger S. AND D. Lombardi. DISPERSION OF ROOF-TOP EMISSIONS FROM ISOLATED BUILDINGS. A WIND TUNNEL STUDY. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/4-77/006 (NTIS PB263901), 1977.

Description:

A fluid modeling study of the dispersion of roof-top emissions from rectangular buildings was performed in the meteorological wind tunnel of the EPA Fluid Modeling Facility. The basic building shape was a 0.18 meter cube. Variations included a building twice as wide and buildings twice and three times as high. Each building was placed in a 1.8 meter, simulated, neutral atmospheric boundary layer. Low momentum, non-buoyant emissions were released through an opening at the roof center. Photographs of flow visualization experiments are presented for a qualitative evaluation of the building wakes. Concentration measurements at ground level and aloft are presented for each case at downwind distances within 20 building heights. Concentrations are presented in a non-dimensional form for ease in application to full scale situations.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:01/31/1977
Record Last Revised:12/22/2005
Record ID: 51234