Science Inventory

PROTOTYPE EVALUATION OF COMMERCIAL SECOND GENERATION LOW-NO BURNER PERFORMANCE AND SULFUR CAPTURE

Citation:

Lisauskas, R. AND D. Itse. PROTOTYPE EVALUATION OF COMMERCIAL SECOND GENERATION LOW-NO BURNER PERFORMANCE AND SULFUR CAPTURE. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/7-86/026 (NTIS PB86220407), 1986.

Description:

The report gives results of pilot-scale combustion tests of a Riley Stoker second-generation low-NOx burner combined with dry sorbent injection for SO2 control. The burner design is based on the distributed mixing concept. Combustion tests were conducted at 100 million Btu/hr in EPA's Large Watertube Simulator (LWS) test furnace. Results were obtained for three U.S. coals and two sorbents. NOx was reduced up to 60% with the advanced burner design.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:07/31/1986
Record Last Revised:12/22/2005
Record ID: 50606