Description:
The report gives results of pilot-scale combustion tests of a Riley Stoker second-generation low-NOx burner combined with dry sorbent injection for SO2 control. The burner design is based on the distributed mixing concept. Combustion tests were conducted at 100 million Btu/hr in EPA's Large Watertube Simulator (LWS) test furnace. Results were obtained for three U.S. coals and two sorbents. NOx was reduced up to 60% with the advanced burner design.