Science Inventory

A. P. S. ELECTRO-TUBE EVALUATION

Citation:

Calvert, S., C. Christensen, AND C. Lake. A. P. S. ELECTRO-TUBE EVALUATION. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/2-76/154b.

Description:

The report gives results of an evaluation of an Air Pollution Systems (APS) Inc. Electro-Tube, a wet electrostatic precipitator. Fine particle collection efficiency as a function of particle size was computed from data taken on the Electro-Tube. It was operated at gas flow rates of 16.9, 18.9, and 22.9 cu mA/min at ambient conditions. Titanium dioxide was generated as the test aerosol having an approximate mass mean diameter of 1.2 micrometers (A) with a geometric standard deviation of 2.2. Test results indicated that the overall collection efficiency was 96.9%, 98.2%, and 99.3% for the high, medium, and low gas flow rates, respectively.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 46925