Science Inventory

COMPARISONS BETWEEN MM5 (MODIFIED METHOD 5), OM7 (OREGON METHOD 7), AND DRAFT ASTM MEASUREMENTS OF WOOD STOVE EMISSIONS

Citation:

McCrillis, R., R. Merrill, P. Westlin, G. Weant, AND D. Wagoner. COMPARISONS BETWEEN MM5 (MODIFIED METHOD 5), OM7 (OREGON METHOD 7), AND DRAFT ASTM MEASUREMENTS OF WOOD STOVE EMISSIONS. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/D-86/150 (NTIS PB86223096), 1986.

Description:

The paper compares three candidate sampling methods--the EPA Modified Method 5 (MM5), the Oregon Method 7 (OM7), and the ASTM proposed Method P180--preparatory to selecting a wood stove operating procedure and related emission sampling method. (NOTE: The EPA is developing a New Source Performance Standard for wood burning stoves. This is one of several issues to be resolved during the development process). Five wood stoves (two catalytic, one noncatalytic generic, one noncatalytic high efficiency, and one catalytic fireplace insert) were tested. Results showed good correlations between the emission measurements obtained with each method.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:07/31/1986
Record Last Revised:12/22/2005
Record ID: 46471