Science Inventory

FIELD EVALUATION OF A MODIFIED VOST SAMPLING METHOD

Citation:

Jackson, M., L. Johnson, R. Fuerst, J. McGaughey, J. Bursey, AND R. Merrill, Jr. FIELD EVALUATION OF A MODIFIED VOST SAMPLING METHOD. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/A-94/150 (NTIS PB94197506), 1994.

Description:

A field test was performed to evaluate a possible replacement sorbent for sampling volatile organic compounds in stationary sources using SW-846 Method 0030. n the basis of laboratory results, Anasorb 747 was selected for testing in the field using dynamic spiking procedures. his modification of the VOST method uses a single tube containing Anasorb 747 that is preceded by two tubes containing Tenax. he modified VOST method was compared in the field with the VOST method using traditional adsorbents. oth the VOST and modified VOST used a quadruple probe and four similar sampling trains. nown amounts of the analytes were introduced into the sampling trains, using the same certified compressed gas cylinder as a source of test compounds. s a general observation, the recovery and precision of most compounds is improved by using the modified VOST procedure.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:12/31/1994
Record Last Revised:12/22/2005
Record ID: 46117