Science Inventory

EFFECT OF AERATION BASIN CONFIGURATION ON BULKING AT LOW ORGANIC LOADING

Citation:

Lee, S., B. Koopman, AND D. Jenkins. EFFECT OF AERATION BASIN CONFIGURATION ON BULKING AT LOW ORGANIC LOADING. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/2-82/081 (NTIS PB82234287), 1982.

Description:

Continuous-flow laboratory-scale activated sludge units were operated on domestic sewage at low F/M. In CSTR units at the F/M range of 0.05-0.25 g COD removed/g TMLVSS, day, bulking did not occur with a weak (BOD(5) = 139 mg/L) sewage feed and TMLSS = 1.5 g/L. Supplementation of sewage by blending with raw sludge produced a stronger sewage (BOD(5) = 315 mg/L) which caused TMLSS to increase to 3.5 g/L. Bulking occurred in CSTR, 2, 4, 8, and 16 compartment units. An aeration basin with initial compartment 1/32nd of aeration basin volume prevented but did not cure bulking. An aeration basin with initial compartments 1/74th of aeration basin volume, prevented and cured bulking. Anoxia in an aeration basin with two initial compartments each 1/64th of the total aeration basin volume did not aid in curing bulking. The SVI of sludges at low F/M (0.3-0.35 g COD removed/g TMLVSS, day) and high TMLSS (3.5 g/L) is related to conditions in the initial compartment rather than those in the remainder of the aeration basin. Initial compartment soluble COD, first-compartment F/M, and initial compartment size are important; floc loading, dispersion number and total number of aeration basin compartments are not important.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:07/31/1982
Record Last Revised:12/22/2005
Record ID: 43107