Calvert, S., S. Yung, AND L. Sparks. LIQUID ENTRAINMENT FROM A MOBILE BED SCRUBBER. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/J-77/177 (NTIS PB81129959).

Description:

The paper gives results of the measurement of liquid entrainment rate and drop size distribution in the exhaust gas stream from a mobile bed scrubber. The pilot plant scrubber was 46 cm square and was packed with 3.8 cm diameter hollow polyethylene spheres to a static depth of 25 cm. Entrainment flow depends on both gas and liquid rates. At a liquid/gas ratio of 6.7 l/cu m and a superficial gas velocity of 2.6 m/sec, the entrainment flow rate was 0.0064 l/cu m; at 3.75 m/sec, it was 0.031 l/cu m. The mass median drop diameter was about 400 micrometers at a liquid/gas ratio of 6.7 l/cu m. The drop size distribution appears to be bimodal. Dye impregnated paper and cascade impactor techniques were used to measure drop size.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:12/10/2002
Record ID: 41798