Science Inventory

SEPARATION OF HAZARDOUS ORGANICS BY LOW PRESSURE REVERSE OSMOSIS MEMBRANES - PHASE II FINAL REPORT

Citation:

Bhattacharyya, D. AND M. Williams. SEPARATION OF HAZARDOUS ORGANICS BY LOW PRESSURE REVERSE OSMOSIS MEMBRANES - PHASE II FINAL REPORT. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/2-91/045.

Description:

Extensive experimental studies shoved that thin-film, composite membranes can be used effectively for the separation of selected hazardous organic compounds. his waste treatment technique offers definite advantages in terms of high solute separations at low pressures (<2MPa) and broad pH operating range, and the use of charged membranes would allow the selective separation of some organics from feeds containing high salt concentrations. n addition feed pre-ozonation of selected organics provided significant improvement in flux and rejection characteristics for both charged and uncharged membranes because of the formation of ionizable organic acid intermediates during the ozonation that did not interact as strongly with the membrane. he overall ozonation/membrane process effectively produced permeate water of high quality while it minimized the volume of waste that must be further treated.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 41778