Science Inventory

DEMONSTRATION OF FUEL CELLS TO RECOVER ENERGY FROM LANDFILL GAS: PHASE II. PRETREATMENT SYSTEM PERFORMANCE MEASUREMENT

Citation:

Trocciola, J. DEMONSTRATION OF FUEL CELLS TO RECOVER ENERGY FROM LANDFILL GAS: PHASE II. PRETREATMENT SYSTEM PERFORMANCE MEASUREMENT. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/R-95/155.

Description:

The report describes-Phase II of a demonstration of the utilization of commercial phosphoric acid fuel cells to recover energy from landfill gas. his phase consisted primarily of the construction and testing of a Gas Pretreatment Unit (GPU) whose function is to remove those impurities from landfill gas which are detrimental to the fuel cell. he GPU has been successfully tested at a landfill in Los. ngeles (Sun Valley), California. he site is operated by Pacific Energy Corp. as a landfill-to-energy facility. he GPU successfully removed the sulfur and halogen compounds contained in the landfill gas to a level significantly below that specified for use with the phosphoric acid fuel cell. uring a challenge test in which dichlorodifluoromethane (Refrigerant 12) was intentionally injected into the process stream during an 8-hour period, the exit concentration of the Refrigerant 12 was below the limit of detection and below the specified value for the fuel cell.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 41360