Science Inventory

CONTROL OF INDUSTRIAL VOC (VOLATILE ORGANIC COMPOUND) EMISSIONS BY CATALYTIC INCINERATION. VOLUME 4. CATALYTIC INCINERATOR PERFORMANCE AT INDUSTRIAL SITE C-2

Citation:

Blacksmith, J. AND J. Randall. CONTROL OF INDUSTRIAL VOC (VOLATILE ORGANIC COMPOUND) EMISSIONS BY CATALYTIC INCINERATION. VOLUME 4. CATALYTIC INCINERATOR PERFORMANCE AT INDUSTRIAL SITE C-2. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/2-84/118D.

Description:

Radian Corporation is conducting a testing program for the U.S. Environmental Protection Agency to evaluate the performance of catalytic incinerators that are applied to industrial processes for volatile organic compound (VOC) control. This report documents the results of the performance testing of a catalytic incinerator operating to control VOC emissionS from printing line number 3 at Plant C-2, a graphic arts printing establishment. The incinerator and its relationship to the printing process are discussed in Section 2. The sampling and analytical procedures used to test the Plant C-2 catalytic incinerator are briefly presented in Section 3, and the results of the abbreviated test are summarized in Section 4. Finally, all data obtained during this portion of the test program are appended.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 40492