Science Inventory

WASTE MINIMIZATION ASSESSMENT FOR A MANUFACTURER OF METAL-PLATED DISPLAY RACKS

Citation:

Looby, G. AND F. Kirsch. WASTE MINIMIZATION ASSESSMENT FOR A MANUFACTURER OF METAL-PLATED DISPLAY RACKS. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/S-92/019.

Description:

The U.S. Environmental Protection Agency (EPA) has funded a pilot project to assist small- and medium-size manufacturers who want to minimize their generation of waste but who lack the expertise to do so. Waste Minimization Assessment Centers (WMACs) were established t selected universities and procedures were adapted from the EPA Waste Minimization Opportunity Assessment Manual (EPA/625/7-88/003, July 1988). he WMAC team at the University of Tennessee performed an assessment at a plant manufacturing metal-plated display racks. teel wire, tubing, and sheets undergo machining operations, and the resulting parts are then nickel and brass-plated, nickel-plated, zinc-plated, nickel and chrome-plated, or painted. he various finished parts are assembled Into display racks. he team's report, detailing findings and recommendations, indicated that the majority of waste was generated by the plating lines and that the greatest waste reduction would result rom utilizing a Zero Discharge Recovery system in the nickel-plating baths. his Research Brief was developed by the principal investigators and EPA's Risk Reduction Engineering Laboratory, Cincinnati, OH, to announce key findings of an ongoing research project that is fully documented in a separate report of the same title available from the authors.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 40191