Science Inventory

ENVIRONMENTAL ASSESSMENT OF A WOOD-WASTE-FIRED INDUSTRIAL FIRETUBE BOILER. VOLUME 1. TECHNICAL RESULTS

Citation:

DeRosier, R. AND L. Waterland. ENVIRONMENTAL ASSESSMENT OF A WOOD-WASTE-FIRED INDUSTRIAL FIRETUBE BOILER. VOLUME 1. TECHNICAL RESULTS. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/7-87/010A.

Description:

The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue gas emissions: source assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of samples to give total flue gas organics in two boiling point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO2 and SO3; and grab sampling of boiler bottom ash for trace element content determinations. Total organic emissions from the boiler were 5.7 mg/dscm, about 90% of which consisted of volatile compounds.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 39622