Science Inventory

ASSESSMENT OF THE IMMUNE RESPONSIVENESS OF MICE IRRADIATED WITH CONTINUOUS WAVE OR PULSE-MODULATED 425-MHZ RADIO FREQUENCY RADIATION

Citation:

Smialowicz, R., M. Riddle, C. Weil, P. Brugnolotti, AND J. Kinn. ASSESSMENT OF THE IMMUNE RESPONSIVENESS OF MICE IRRADIATED WITH CONTINUOUS WAVE OR PULSE-MODULATED 425-MHZ RADIO FREQUENCY RADIATION. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/J-82/007 (NTIS PB83188987).

Description:

Groups of female BALB/C mice were irradiated with 425-MHz radio frequency (RF) radiation either continuous wave (CW) or pulse modulated (PM, 1-ms pulse width, 250 pulses/s). Mice were irradiated in a rectangular strip-transmission line at average forward powers of 78, 17.7, or 5 W for CW and 17.7, 5, or 1.25 W for PM. The mean specific absorption rate, as measured using twin-well calorimetry was 7.7 W/kg for a forward power of 70 W. No differences in the mitogen-stimulated response of lymphocytes or in the primary antibody response to sheep erythrocytes or polyvinylpyrrolidone were observed between irradiated and sham-irradiated mice, nor between mice exposed to either CW or PM 425-MHz RF radiation.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 36228