Science Inventory

PERFORMANCE AUDIT PROCEDURES FOR OPACITY MONITORS

Citation:

Plaisance, S. AND J. Peeler. PERFORMANCE AUDIT PROCEDURES FOR OPACITY MONITORS. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/8-87/025.

Description:

The manual contains monitor-specific performance audit procedures and data forms for use in conducting audits of installed opacity continuous emission monitoring systems (CEMS). General auditing procedures and acceptance limits for various audit criteria are discussed. Practical considerations and common problems encountered in conducting audits are delineated, and recommendations are included to optimize the successful completion of performance audits. Performance audit procedures and field data forms were developed for six common opacity CEMS: (1) Lear Siegler, Inc. Model RM-41; (2) Lear Siegler, Inc. Model RM-4; (3) Dynatron Model 1100; (4) Thermo Electron, Inc. Model 400; (5) Thermo Electron, Inc. Model 1000A; and (6) Enviroplan Model D-R280 AV. Generic audit procedures have been included for use in evaluating opacity CEMS with multiple transmissometers and combiner devices. In addition, several approaches for evaluating the zero alignment or 'clear-path' zero response have been described. The zero alignment procedures have been included since the factor is fundamental to the accuracy of opacity monitoring data, even though the zero alignment checks cannot usually be conducted during a performance audit.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 35724