KRESS INDIRECT DRY COOLING SYSTEM - BETHLEHEM STEEL'S COKE PLANT DEMONSTRATION AT SPARROWS POINT, MARYLAND - VOLUME 2. APPENDICES G-N

Citation:

Ossman, A. KRESS INDIRECT DRY COOLING SYSTEM - BETHLEHEM STEEL'S COKE PLANT DEMONSTRATION AT SPARROWS POINT, MARYLAND - VOLUME 2. APPENDICES G-N. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/R-93/080b.

Description:

The report evaluates the Kress Indirect Dry Cooling (KIDC) process, an innovative system for handling and cooling coke produced from a slot-type by-product coke oven battery. he report is based on the test work and demonstration of the system at Bethlehem Steel Corporation's Sparrows Point (Maryland) facility in 1991. he report covers both environmental and operational impacts of the KIDC process. reas covered in the report include opacity levels, quenching emissions, and the impact of the KIDC coke on blast furnace operations. lso evaluated were various performance characteristics of the KIDC system, including reliability, cycle time, coke cooling requirements, and costs. nfortunately, abbreviation of the test program, caused by the idling of coke production at Sparrows Point, limited the experience gained and data collected during the demonstration. he report data have not been thoroughly audited, and the conclusions are neither approved nor endorsed by EPA. ecause of the sudden termination of the project and the associated quality assurance effort, it was not possible to perform the detailed laboratory and data audits that had been planned.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 35645