Science Inventory

PREVENTION REFERENCE MANUAL: CHEMICAL SPECIFIC. VOLUME 2. CONTROL OF ACCIDENTAL RELEASES OF CHLORINE (SCAQMD) (SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT)

Citation:

Davis, D., G. DeWolf, J. Quass, AND K. Wert. PREVENTION REFERENCE MANUAL: CHEMICAL SPECIFIC. VOLUME 2. CONTROL OF ACCIDENTAL RELEASES OF CHLORINE (SCAQMD) (SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT). U.S. Environmental Protection Agency, Washington, D.C., EPA/600/8-87/034B.

Description:

The manual discusses reducing the risk associated with an accidental release of chlorine. It identifies some of the potential causes of accidental releases that apply to the processes that use chlorine. It also identifies examples of potential causes, as well as measures that may be taken to reduce the accidental release risk. Such measures include recommendations on: plant design practices; prevention, protection, and mitigation technologies; and operation and maintenance practices. It provides conceptual cost estimates of possible prevention, protection, and mitigation measures. Chlorine is a highly reactive and corrosive liquid that boils at room temperature. It has an IDLH (immediately dangerous to life and health) concentration of 25 ppm, which makes it a substantial acute toxic hazard. Accidental releases of toxic chemicals at Bhopal and Chernobyl have increased public awareness of toxic release problems. As a result of other, perhaps less dramatic incidents in the past, portions of the chemical industry were aware of this problem long before these events. These same portions of the industry have made advances in the area.

Record Details:

Record Type:DOCUMENT( REPORT )
Product Published Date:05/24/2002
Record Last Revised:04/16/2004
Record ID: 33864