Science Inventory

Performance Evaluation of a Low-Cost, Real-Time Community Air Monitoring Station

Citation:

Jiao, W., G. Hagler, R. Williams, B. Sharpe, J. Rice, AND Lewis Weinstock. Performance Evaluation of a Low-Cost, Real-Time Community Air Monitoring Station. Presented at American Association of Aerosol Research annual meeting, Orlando, FL, October 20 - 24, 2014.

Impact/Purpose:

The purpose of this abstract is to propose a talk on the Village Green Project at the American Association of Aerosol Research annual meeting.

Description:

The US EPA’s Village Green Project (VGP) is an example of using innovative technology to enable community-level low-cost real-time air pollution measurements. The VGP is an air monitoring system configured as a park bench located outside of a public library in Durham, NC. It contains air monitoring and meteorological instruments that measure PM2.5 (Thermo pDR-1500), ozone (2B Technologies), temperature, relative humidity, wind speed, and direction. These instruments are integrated together using an Arduino microcontroller with real-time data streamed wirelessly using an Ethernet gateway to a cloud database once every minute. The data are then made available online to the public after automated quality checks. The entire station utilizes solar energy with battery backup to be self-powered and totally off the grid. In the first six months of field sampling since June 2013, the station has successfully collected over 3600 hours of PM2.5 concentration data, with fewer than 10 days of down time due to power loss. To evaluate the VGP sensor system performance, data collected were summarized and compared with measurements made at nearby air monitoring stations operating federal equivalent methods (FEM) for PM2.5 and ozone, with comparisons at hourly and 5-minute average time resolutions. In addition, the use of solar energy to support VGP operation was also assessed. The hourly average VGP PM2.5 concentrations generally co-varied with the nearest benchmark FEM site during sampling period, with a slope of the regression line of 0.96 and r2 of 0.74. Comparison results indicated that design features incorporated in the VGP are promising to enhance air quality and exposure monitoring capacities in community settings, which provide additional air quality data to supplement regulatory monitoring.

URLs/Downloads:

33RD AAAR ABSTRACT_JIAO_20140320DGM.PDF  (PDF, NA pp,  15.458  KB,  about PDF)

Record Details:

Record Type:DOCUMENT( PRESENTATION/ ABSTRACT)
Product Published Date:10/24/2014
Record Last Revised:09/30/2016
OMB Category:Other
Record ID: 326153