Science Inventory

Application of Passive Sampling for Measuring Dissolved Concentrations of Organic Contaminants in the Water Column at Three U.S. EPA Marine Superfund Sites

Citation:

Burgess, R., R. Lohmann, J. Schubauer-Berigan, P. Reitsma, M. Perron, L. Lefkovitz, AND M. Cantwell. Application of Passive Sampling for Measuring Dissolved Concentrations of Organic Contaminants in the Water Column at Three U.S. EPA Marine Superfund Sites. Society of Environmental Toxicology and Chemistry (SETAC) Europe 25th Annual Meeting, Barcelona, SPAIN, May 03 - 07, 2015.

Impact/Purpose:

The purpose of this investigation was to evaluate the use of passive sampling for measuring water column Cfree for several HOCs at three U.S. EPA Superfund sites. Sites investigated included New Bedford Harbor, Palos Verdes Shelf and Naval Station Newport and the passive samplers evaluated were polyethylene (PE), solid phase microextraction (SPME), semi-permeable membrane devices (SPMD) and polyoxymethylene (POM). In general, the different passive samplers demonstrated good agreement with Cfree values varying by a factor of two to three. These findings suggest that all of the samplers were experiencing and measuring similar Cfree during their respective deployments. This evaluation demonstrates the utility of passive sampling for generating scientifically accurate water column Cfree which is critical for making informed environmental management decisions at contaminated sediment sites.

Description:

At contaminated sediment sites, including U.S. EPA Superfund sites, it is critical to measure water column concentrations of freely dissolved contaminants to understand the complete exposure of aquatic organisms to hydrophobic organic contaminants (HOCs). Historically acquiring the freely dissolved concentration (Cfree) of HOCs was challenging. In recent years, passive sampling has been demonstrated to be an effective tool for determining Cfree in the water column and in sediment interstitial waters. Currently, there is an effort underway encouraging remedial project managers (RPMs) at contaminated sites to use passive sampling to collect Cfree data in order to improve site assessments. The objective of this investigation was to evaluate the use of passive sampling for measuring water column Cfree for several HOCs at three U.S. EPA Superfund sites. Sites investigated included New Bedford Harbor, Palos Verdes Shelf and Naval Station Newport and the passive samplers evaluated were polyethylene (PE), solid phase microextraction (SPME), semi-permeable membrane devices (SPMD) and polyoxymethylene (POM). In general, the different passive samplers demonstrated good agreement with Cfree values varying by a factor of two to three. This level of agreement was demonstrated, in particular, at Palos Verdes Shelf where elevated Cfree determined by different types of passive samplers deployed in studies over several years varied by less than a factor of two (i.e., 320 to 460 pg/L for sum of polychlorinated biphenyls, PCBs). Further, at New Bedford Harbor, where conventional water sample concentrations were also measured (i.e., grab samples), passive sampler-based Cfree agreed within a factor of two. These findings suggest that all of the samplers were experiencing and measuring similar Cfree during their respective deployments. This evaluation demonstrates the utility of passive sampling for generating scientifically accurate water column Cfree which is critical for making informed environmental management decisions at contaminated sediment sites.

URLs/Downloads:

RB_SETAC EUROPE_2015.PDF  (PDF, NA pp,  38.842  KB,  about PDF)

Record Details:

Record Type:DOCUMENT( PRESENTATION/ ABSTRACT)
Product Published Date:06/02/2015
Record Last Revised:06/02/2015
OMB Category:Other
Record ID: 308077