Kurhanewicz, N., R. McIntosh-Kastrinsky, H. Tong, L. Walsh, A. Farraj, AND M. Hazari. Ozone co-exposure modifies cardiac responses to fine and ultrafine ambient particulate matter in mice: concordance of electrocardiogram and mechanical responses. Particle and Fibre Toxicology. BioMed Central Ltd, London, Uk, 11(1):54, (2014).

Impact/Purpose:

The purpose of this study was to determine the effect of simultaneous exposure to concentrated ambient particles (CAPs) and ozone on cardiovascular function in mice. This work addresses OAR's question of synergism, additivism in multipollutant exposures and the Agency's questions on cardiovascular health effects of particulate matter.

Description:

BackgroundStudies have shown a relationship between air pollution and increased risk of cardiovascular morbidity and mortality. Due to the complexity of ambient air pollution composition, recent studies have examined the effects of co-exposure, particularly particulate matter (PM) and gas, to determine whether pollutant interactions alter (e.g. synergistically, antagonistically) the health response. This study examines the independent effects of fine (FCAPs) and ultrafine (UFCAPs) concentrated ambient particles on cardiac function, and determine the impact of ozone (03) co-exposure on the response. We hypothesized that UFCAPs would cause greater decrement in mechanical function and electrical dysfunction than FCAPs, and that 03 co­ exposure would enhance the effects of both particle- types. MethodsConscious/unrestrained radiotelemetered mice were exposed once whole-body to either 190 ug/m3 FCAPs or 140 ug/m3 UFCAPs with/without 0.3 ppm 03; separate groups were exposed to either filtered air (FA) or 03 alone. Heart rate (HR) and electrocardiogram (ECG) were recorded continuously before, during and after exposure, and cardiac mechanical function was assessed using a Langendorff perfusion preparation 24 hrs post-exposure.ResultsFCAPs alone caused a significant decrease in baseline left ventricular developed pressure (LVDP) and contractility, whereas UFCAPs did not; neither FCAPs nor UFCAPs alone caused any ECG changes. 03 co-exposure with FCAPs caused a significant decrease in heart rate variability when compared to FA but also blocked the decrement in cardiac function. On the other hand, 03 co-exposure with UFCAPs significantly increased QRS-interval, QTc and non-conducted P-wave arrhythmias, and decreased LVDP, rate of contractility and relaxation when compared to controls.ConclusionsThese data suggest that particle size and gaseous interactions may play a role in cardiac function decrements one day after exposure. Although FCAPs,+,03 only altered autonomic balance, UFCAPs,+,03 appeared to be more serious by increasing cardiac arrhythmias and causing mechanical decrements. As such, 03 appears to interact differently with FCAPs and UFCAPs, resulting in varied cardiac changes, which suggests that the cardiovascular effects of particle-gas co­ exposures are not simply additive or even generalizable. Additionally, the mode of toxicity underlying this effect may be subtle given none of the exposures described here impaired post­ ischemia recovery.

URLs/Downloads:

ORD-007223-ABSTRACT.PDF  (PDF, NA pp,  300.371  KB,  about PDF)

Record Details:

Record Type:DOCUMENT( JOURNAL/ PEER REVIEWED JOURNAL)
Product Published Date:10/16/2014
Record Last Revised:04/03/2015