Science Inventory

Dustborne and airborne gram-positive and gram-negative bacteria in high versus low ERMI homes

Citation:

Adhikari, A., E. Kettleson, S. Vesper, S. Kumar, D. Popham, C. Schaffer, R. Indugula, K. Chatterjee, K. Allam, S. Grinshpun, AND T. Reponen. Dustborne and airborne gram-positive and gram-negative bacteria in high versus low ERMI homes. SCIENCE OF THE TOTAL ENVIRONMENT. Elsevier BV, AMSTERDAM, Netherlands, 482(1):92-99, (2014).

Impact/Purpose:

During the 2010 external peer review of the ERMI, the reviewers recommended that consideration also be given to bacterial contamination in the home. This paper is part of the effort to complete that request.

Description:

The study aimed at investigating Gram-positive and Gram-negative bacteria in moldy and non-moldy homes, as defined by the home's Environmental Relative Moldiness Index (ERMI) value. The ERMI values were determined from floor dust samples in 2010 and 2011 and homes were classified into low (b5) and high (N5) ERMI groups based on the average ERMI values as well as 2011 ERMI values. Dust and air samples were collected from the homes in 2011 and all samples were analyzed for Gram-positive and Gram-negative bacteria using QPCR assays,endotoxin by the LAL assay, and N-acetyl-muramic acid using HPLC. In addition, air samples were analyzed for culturable bacteria. When average ERMI values were considered, the concentration and load of Gram-positive bacteria determined with QPCR in house dust, but not air, were significantly greater in high ERMI homes than in low ERMI homes. Furthermore, the concentration of endotoxin, but not muramic acid, in the dust was significantly greater in high ERMI than in low ERMI homes. In contrast, when ERMI values of 2011 were considered,Gram-negative bacteria determined with QPCR in air, endotoxin in air, and muramic acid in dust were significantly greater in high ERMI homes. The results suggest that both short-term and long-term mold contamination in homes could be linked with the bacterial concentrations in house dust, however, only the current mold status was associated with bacterial concentrations in air. Although correlations were found between endotoxin and Gram-negative bacteria as well as between muramic acid and Gram-positive bacteria in the entire data set,diverging associations were observed between the different measures of bacteria and the home moldiness. It is likely that concentrations of cells obtained by QPCR and concentrations of cell wall components are not equivalent and represent too broad categories to understand the bacterial composition and sources of the home microbiota

URLs/Downloads:

j.scitotenv.2014.02.110   Exit EPA's Web Site

Record Details:

Record Type:DOCUMENT( JOURNAL/ PEER REVIEWED JOURNAL)
Product Published Date:06/01/2014
Record Last Revised:06/03/2014
OMB Category:Other
Record ID: 275630