Office of Research and Development Publications

Surface Analysis of Nerve Agent Degradation Products by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

Citation:

U.S. EPA. Surface Analysis of Nerve Agent Degradation Products by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS). U.S. Environmental Protection Agency, Washington, DC, 2013.

Impact/Purpose:

This sampling and analytical procedure was developed and applied by a single laboratory to investigate nerve agent degradation products, which may persist at a contaminated site, via surface wiping followed by analytical characterization. The performance data presented demonstrate the fitness-for-purpose regarding surface analysis in that single laboratory. Surfaces (laminate, glass, galvanized steel, vinyl tile, painted drywall and treated wood) were wiped with cotton gauze wipes, sonicated, extracted with distilled water, and filtered. Samples were analyzed with direct injection electrospray ionization liquid chromatography tandem mass spectrometry (ESI-LC/MS/MS) without derivatization. Detection limit data were generated for all analytes of interest on a laminate surface. Accuracy and precision data were generated from each surface fortified with these analytes.

Description:

Report

Record Details:

Record Type:DOCUMENT( PUBLISHED REPORT/ METHODOLOGY)
Product Published Date:09/30/2013
Record Last Revised:11/18/2013
OMB Category:Other
Record ID: 259938