Science Inventory

A High Frequency Response Relaxed Eddy Accumulation Flux Measurement System for Sampling Short-Lived Biogenic Volatile Organic Compounds

Citation:

Arnts, R. R., F. L. Mowry, AND G. A. Hampton. A High Frequency Response Relaxed Eddy Accumulation Flux Measurement System for Sampling Short-Lived Biogenic Volatile Organic Compounds. JOURNAL OF GEOPHYSICAL RESEARCH: ATMOSPHERES. American Geophysical Union, Washington, DC, 118(10):4860-4873, (2013).

Impact/Purpose:

The National Exposure Research Laboratory′s (NERL′s) Human Exposure and Atmospheric Sciences Division (HEASD) conducts research in support of EPA′s mission to protect human health and the environment. HEASD′s research program supports Goal 1 (Clean Air) and Goal 4 (Healthy People) of EPA′s strategic plan. More specifically, our division conducts research to characterize the movement of pollutants from the source to contact with humans. Our multidisciplinary research program produces Methods, Measurements, and Models to identify relationships between and characterize processes that link source emissions, environmental concentrations, human exposures, and target-tissue dose. The impact of these tools is improved regulatory programs and policies for EPA.

Description:

A second-generation relaxed eddy accumulation system was built and tested with the capability to measure vertical biogenic volatile organic compound (VOC) fluxes at levels as low as 10 µg C m−2 hr−1. The system features a continuous, integrated gas-phase ozone removal procedure to allow for the measurement of highly reactive species such as β-caryophyllene and polar terpenoids such as linalool. A two-component internal standard continuously added to the accumulators was used to correct for switching-induced volumetric errors and as a check on VOC losses exceeding accumulator tube adsorption limits. In addition, the internal standards were used to demonstrate that accumulators quickly return to target flow rates at segregation valve switching frequencies up to at least 0.8 Hz. The system was able to measure daytime hourly fluxes of individual biogenic VOC including oxygenated terpenoids, monoterpenes, and sesquiterpenes.

Record Details:

Record Type:DOCUMENT( JOURNAL/ PEER REVIEWED JOURNAL)
Product Published Date:05/27/2013
Record Last Revised:07/23/2013
OMB Category:Other