Science Inventory

Arsenic Removal from Drinking Water by Coagulation/Filtration U.S. EPA Demonstration Project at Town of Felton, DE, Final Performance Evaluation Report

Citation:

Chen, A., G. M. Lewis, A. Wang, AND L. Wang. Arsenic Removal from Drinking Water by Coagulation/Filtration U.S. EPA Demonstration Project at Town of Felton, DE, Final Performance Evaluation Report. U.S. Environmental Protection Agency, Washington, DC, EPA/600/R-10/039, 2010.

Impact/Purpose:

To inform the public.

Description:

This report documents the activities performed during and the results obtained from the arsenic removal treatment technology demonstration project at the Town of Felton, DE. The objectives of the project were to evaluate: (1) the effectiveness of Kinetico’s FM-348-AS coagulation/filtration (C/F) system using Macrolite® media in removing arsenic to meet the maximum contaminant level (MCL) of 10 µg/L, (2) the reliability of the C/F system for use at small water facilities, (3) the required system operation and maintenance (O&M) and operator skill levels, and (4) the capital and O&M cost of the technology. The project also characterized water in the distribution system and residuals generated by the treatment process. The types of data collected included system operation, water quality, process residuals, and capital and O&M cost.

Record Details:

Record Type:DOCUMENT( PUBLISHED REPORT/ REPORT)
Product Published Date:06/30/2010
Record Last Revised:07/13/2011
OMB Category:Other
Record ID: 222104