NHEXAS PHASE I REGION 5 STUDY--METALS IN WATER ANALYTICAL RESULTS
Notice:
WARNING! DATA USE RESTRICTIONS
Read Carefully Before Using
The EPA does all it can to ensure that the identity of survey participants cannot be disclosed. All direct identifiers, as well as any characteristics that might lead to identifications, are omitted from the data. Any intentional identification or disclosure of a person or establishment violates the assurances of confidentiality given to the providers of the information. Therefore, users will (1) use the data in this study for statistical reporting and analysis only; (2) make no use of the identity of any person or establishment discovered inadvertently and will advise the HEDS Administrator of any such discovery; (3) will not link this data with individually identifiable data from other EPA or non-EPA data.
By using the data you signify your agreement to comply with the above-stated statutorily based requirements.
Description:
This data set includes analytical results for measurements of metals in 905 water samples. Standing tap water, collected from the kitchen tap after water in the home plumbing was undisturbed for 4 hours, was analyzed to assess the contribution of home plumbing to exposure to metals, particularly lead from plumbing solder joints. Flushed tap water, collected after water has been run through the pipes for 3 minutes, was analyzed to assess potential contamination with metals from the water source or supply. For participants who were not collecting duplicate diet samples, separate samples of drinking water were collected if tap water was not the primary source of drinking water. All samples were collected in 250 mL polyethylene containers, refrigerated in the field, shipped cold to the analysis laboratory, and acidified upon receipt at the lab. Samples were acid extracted and digested, and analyzed by Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) for lead, cadmium, chromium, and arsenic following EPA Method 200.8. Keywords: metals; water.
The National Human Exposure Assessment Survey (NHEXAS) is a federal interagency research effort coordinated by the Environmental Protection Agency (EPA), Office of Research and Development (ORD). Phase I consists of demonstration/scoping studies using probability-based sampling designs. The Region 5 study was conducted in EPA's Region 5 (Ohio, Michigan, Illinois, Indiana, Wisconsin, and Minnesota), and included personal exposure, residential concentration, and biomarker measurements of metals and VOCs. The study was conducted by the Research Triangle Institute (RTI) and the Environmental and Occupational Health Sciences Institute (EOHSI). The scope and design of the study are detailed in the following article: E. Pellizzari et al., Population-Based Exposure Measurements in EPA Region 5: A Phase I Field Study in Support of the National Human Exposure Assessment Survey. Journal of Exposure Analysis and Environmental Epidemiology, Vol. 5, No. 3, 1995, pp. 327-358.
NOTE: The U.S. Environmental Protection Agency (EPA), through its Office of Research and Development (ORD), partially funded and collaborated in the research described here. Mention of trade names or commercial products does not constitute endorsement or recommendation by EPA for use.
Record Details:
Record Type:DATA SET
Product Published Date:12/31/1997
Record Last Revised:12/10/2002
Record ID:
17539
Related Records:
NHEXAS PHASE I REGION 5 STUDY--QUALITY SYSTEMS AND IMPLEMENTATION PLAN FOR HUMAN EXPOSURE ASSESSMENT STUDY (RTI/5740/02-02QSIP)
Relationship Reason:NHEXAS PHASE I REGION 5 STUDY--QUALITY SYSTEMS AND IMPLEMENTATION PLAN FOR HUMAN EXPOSURE ASSESSMENT STUDY (RTI/5740/02-02QSIP)16579DOCUMENT1.0APPLICABLE QUALITY SYSTEMS AND IMPLEMENTATION PLANREVIEWEDPUBLICORDNERL
NHEXAS PHASE I REGION 5 STUDY
Relationship Reason:NHEXAS PHASE I REGION 5 STUDY17945PROJECT1.0APPLICABLE STUDYREVIEWEDPUBLICORDNERL
NHEXAS PHASE I REGION 5 STUDY--LIST OF STUDY DOCUMENTS: PROTOCOLS AND SOPS
Relationship Reason:NHEXAS PHASE I REGION 5 STUDY--LIST OF STUDY DOCUMENTS: PROTOCOLS AND SOPS18199DOCUMENT1.0REFERENCE DOCUMENTSREVIEWEDPUBLICORDNERL
NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHODS FOR ANALYSIS OF METALS AND VOCS IN WATER (EPA-COMPENDIUM)
Relationship Reason:NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHODS FOR ANALYSIS OF METALS AND VOCS IN WATER (EPA-COMPENDIUM)17360DOCUMENT1.0APPLICABLE SOP FOR SAMPLE ANALYSISREVIEWEDPUBLICORDNERL
NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF DRINKING WATER SAMPLES FOR VOCS BY EPA METHOD 524.2 (RTI/ACS-AP-209-003)
Relationship Reason:NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF DRINKING WATER SAMPLES FOR VOCS BY EPA METHOD 524.2 (RTI/ACS-AP-209-003)16880DOCUMENT1.0APPLICABLE SOP FOR SAMPLE COLLECTIONREVIEWEDPUBLICORDNERL
NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF FLUSH AND DRINKING WATER OR DRINKING WATER SAMPLES FOR METALS AND ARSENIC BY EPA METHOD 200.8 (RTI/
Relationship Reason:NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF FLUSH AND DRINKING WATER OR DRINKING WATER SAMPLES FOR METALS AND ARSENIC BY EPA METHOD 200.8 (RTI/16879DOCUMENT1.0APPLICABLE SOP FOR SAMPLE COLLECTIONREVIEWEDPUBLICORDNERL
NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF STANDING TAP WATER SAMPLES FOR METALS AND ARSENIC BY EPA METHOD 200.8 (RTI/ACS-AP-209-001)
Relationship Reason:NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF STANDING TAP WATER SAMPLES FOR METALS AND ARSENIC BY EPA METHOD 200.8 (RTI/ACS-AP-209-001)16860DOCUMENT1.0APPLICABLE SOP FOR SAMPLE COLLECTIONREVIEWEDPUBLICORDNERL
Related Organizations:
Role
:CONTACT
Organization Name
:U.S. EPA Human Exposure and Atmospheric Sciences Division
Primary Email
:admin.heds@epa.gov
Mailing Address
:P.O. Box 93478
Citation
:Las Vegas
State
:NV
Zip Code
:891933478
Quality Assurance:
Title
:NHEXAS PHASE I REGION 5 STUDY--METALS IN WATER ANALYTICAL RESULTS
Data Use & Constraints
:NHEXAS is a rich source of data. EPA encourages you to use the data for research and analysis. User familiarity with data file manipulation and analysis is required. EPA does not have the resources to perform analyses, check results, debug programs, or do literature review for your work. Thorough review of the documentation on the survey's planning, analytic guidelines, and individual datasets available through HEDS and EIMS should resolve most questions. If you still have questions after careful review of the documentation, please contact the Human Exposure and Atmospheric Sciences Division at (919) 541-3184 or send an e-mail to "admin.heds@epa.gov". Please review the data use restrictions in the Notice field (EIMS Summary page) and your agreement to comply with these restrictions in using the data.
These data are the result of a probability-based sampling design specific to the population under study. Thus the data may or may not be representative of subsets of this study's population or of other populations. The study was designed to test certain hypotheses, and this may limit its applicability for other purposes. When using these data it is important to consider the percentage of non-responses or non-detects in the data as an indicator of its usefulness for other purposes. No liability is accepted by the U.S. EPA for any errors or omissions in the results included in the data sets, associated information, and/or documentation.
Based on the output format selected by the user and the software into which the data set is imported, users may notice that measurements and sampling weights are zero-padded to the right of non-zero decimal digits. These zeroes are purely a function of the formatting process and the software's acceptance of that format and should not be construed to represent significant digits in the value. Measurement values are provided with four significant digits; sampling weights are provided with three decimal digits.