Science Inventory

ENVIRONMENTAL TECHNOLOGY VERIFICATION--TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES, CUMMINS EMISSION SOLUTIONS AND CUMMINS FILTRATION DIESEL OXIDATION CATALYST AND CLOSED CRANKCASE VENTILATION SYSTEM

Citation:

RESEARCH TRIANGLE INSTITUTE. ENVIRONMENTAL TECHNOLOGY VERIFICATION--TEST REPORT OF MOBILE SOURCE EMISSION CONTROL DEVICES, CUMMINS EMISSION SOLUTIONS AND CUMMINS FILTRATION DIESEL OXIDATION CATALYST AND CLOSED CRANKCASE VENTILATION SYSTEM. U.S. Environmental Protection Agency, Washington, DC, EPA/600/R-07/078, 2007.

Impact/Purpose:

ETV Report

Description:

The U.S. EPA has created the Environmental Technology Verification (ETV) Program. ETV seeks to provide high-quality, peer-reviewed data on technology performance. The Air Pollution Control Technology (APCT) Verification Center, a center under the ETV Program, is operated by Research Triangle Institute. The APCT Center has evaluated the performance of an emissions control system consisting of the Cummins Emission Solutions and Cummins Filtration's 201350N precious metal diesel oxidation catalyst (DOC) and closed crankcase ventilation system, consisting of the DOC plus the coalescer breather CV5061200 and the crankcase depression regulator valve 395587500.

URLs/Downloads:

NRMRL RTP 407.PDF  (PDF, NA pp,  388  KB,  about PDF)

ETV CUMMINS EMISSION, ETC.  (PDF, NA pp,   KB,  about PDF)

Record Details:

Record Type:DOCUMENT( ETV DOCUMENT)
Product Published Date:07/30/2007
Record Last Revised:03/26/2008
OMB Category:Other
Record ID: 173405