LCDRS FLOW FROM DOUBLE-LINED LANDFILLS AND SURFACE IMPOUNDMENTS. Project Summary (EPA/600/SR-93/070)
Citation:
Bonaparte, R. AND B. A. Gross. LCDRS FLOW FROM DOUBLE-LINED LANDFILLS AND SURFACE IMPOUNDMENTS. Project Summary (EPA/600/SR-93/070). U.S. Environmental Protection Agency, Washington, DC, EPA/600/R-93/070 (NTIS 93-179885), 1993.
Impact/Purpose:
publish information
Description:
A study, sponsored by the U.S. Environmental Protection Agency (EPA), on measured flows from leakage detection, collection, and removal systems (LDCRSs) of 28 double-lined landfills and 8 double-lined surface impoundments indicated — all landfills with geomembrane top liners leaked; — landfills with composite top liners had LDCRS flows from consolidation water; — 60% of surface impoundments with geomembrane top liners leaked; — landfill flows were within the expected range; those from impoundments were lower; — facilities constructed with rigorous construction quality assurance (CQA) report leakage of less than 1,000 liters per hectare per day (L/hd).