Science Inventory

EVALUATION OF INTERNALLY STAGED COAL BURNERS AND SORBENT JET AERODYNAMICS FOR COMBINED SO2/NOX CONTROL IN UTILITY BOILERS; VOLUME 2. TESTING IN A 100 MILLION BTU/HR EXPERIMENTAL FURNACE

Citation:

Cetegen, B., J. Clough, G. England, T. Johnson, Y. Kwan, AND R. Payne. EVALUATION OF INTERNALLY STAGED COAL BURNERS AND SORBENT JET AERODYNAMICS FOR COMBINED SO2/NOX CONTROL IN UTILITY BOILERS; VOLUME 2. TESTING IN A 100 MILLION BTU/HR EXPERIMENTAL FURNACE. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/7-89/009 (NTIS PB90-108846), 1989.

Impact/Purpose:

information

Description:

The report givesresults of100 million Btu/hr (29 MWt) experimental furnace to explore methods for achieving effective S02 removal in a coalfired utility boiler using calcium-based sorbents, through appropriate selection of injection location and injector design/operating parameters. Methods were also tested to reduce NOx emissions from the coal burners without external air ports (i.e., with internal fuel/air staging). orbent jet testing showed that, through cold modelling, injection locations and velocities could be selected which avoided recirculation of the sorbent into the burner zone (hence dead-burning). At the best conditions, S02 removals at Ca/S = 2 were 30-40% with finely ground limestone, 45-50% with dolomite, and 60% with pressure-hydrated dolomitic lime. Limited testing of burner modifications to achieve internal staging resulted in about a 35% reduction in NOx, through use of coal splitters.

URLs/Downloads:

NTISCONTACT.PDF  (PDF, NA pp,  8  KB,  about PDF)

Record Details:

Record Type:DOCUMENT( PUBLISHED REPORT/ REPORT)
Product Published Date:09/30/1989
Record Last Revised:10/07/2008
OMB Category:Other
Record ID: 126116