Science Inventory

EVALUATION OF ROTARY KILN INCINERATOR OPERATION AT LOW TO MODERATE TEMPERATURE CONDITIONS VOLUME 1. TECHNICAL RESULTS

Citation:

Lee, J., D. Fournier, C. King, S. Venkatesh, AND C. Goldman. EVALUATION OF ROTARY KILN INCINERATOR OPERATION AT LOW TO MODERATE TEMPERATURE CONDITIONS VOLUME 1. TECHNICAL RESULTS. U.S. Environmental Protection Agency, Washington, D.C., EPA/600/R-96/105a (NTIS 96-210414), 1996.

Impact/Purpose:

information

Description:

A test program was performed at the Environmental Protection Agency Incineration Research Facility to study the effectiveness of incineration at low-to-moderate temperatures in decontaminating soils containing organic compounds with different volatilities (boiling points). The data demonstrate that compound volatility and treatment temperature are the key parameters. Elevated solid temperature favors decontamination. The extent of decontamination increases with time. The data suggest that a high temperature and a long treatment time are likely to result in the desired level of decontamination. Agitation can also increase the decontamination process of contaminated soils.

URLs/Downloads:

www.ntis.gov   Exit EPA's Web Site

Record Details:

Record Type:DOCUMENT( PUBLISHED REPORT/ REPORT)
Product Published Date:09/01/1996
Record Last Revised:08/13/2008
OMB Category:Other
Record ID: 119345