Determination of Phenols in Environmentally Relevant Matrices With the Use of Liquid Chromatography With An Enzyme Electrode Detector

spacer
spacer
Abstract: A simple and rapid assay using HPLC with a tyrosinase-containing carbon paste electrode (Tyr-CPE) detector is demonstrated for the detection of phenol, p-cresol, p-methoxyphenol, and p-chlorophenol in environmental matrices. These compounds were measured in contaminated aqueous soil leachate samples or ace-tone/acetonitrile extracts of soil and sludge samples. The dynamic range for this assay was 2-30 ppm for phenol and p-cresol. In addition to analysis by the Tyr-CPE detector held at a reducing potential (-0.20 V), soil leachate and extracts were analyzed with the use of a carbon paste electrode (CPE) detector at oxidizing potentials (+1.0 V or +1.2 V). Compared to the CPE, the Tyr-CPE detector was very stable, showing a signal loss of only 28% over 24 h of continuous operation. In addition, the signal from the CPE degraded rapidly by 65% over 10 sequential injections, whereas the signal of the Tyr-CPE decreased by only 5% for the same number of sequential injections. Because of the minimal sample preparation for analysis of soil leachate samples, the herein-reported chromatographic system with biosensor detector could be further developed to complement portable tyrosinase enzyme electrode biosensors that detect total phenols in field settings.

The U.S. Environmental Protection Agency (EPA), through its Office of Research and Development (ORD), partially funded the work involved in preparing this article. It has been subjected to the EPA's peer and administrative review and has been approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation by EPA for use.
spacer
Citation:Rogers, K. R., J. Becker, J. Wang, and F. Lu. Determination of Phenols in Environmentally Relevant Matrices With the Use of Liquid Chromatography With An Enzyme Electrode Detector. FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY 3(3):161-169, (1999).
spacer
spacer
Contact: Liz Hope - (919) 541-2785 or hope.elizabeth@epa.gov
spacer
Division: Human Exposure & Atmospheric Sciences Division
spacer
Branch: Human Expsoure Research Branch
spacer
Product Type: Journal
spacer
Published: 03/18/1999
spacer
Related Entries:
spacer
Bullet Item Biosensors Research for Development of Innovative Monitoring Techniques That Support Exposure Assessment Related to the Superfund Program
spacer Relationship Reason:   A Project of the Product
spacer
spacer
spacer

 

ORD Home | Search EPA | Search NERL | Search EIMS | Contacts | Help

 
Begin Site Footer

EPA Home | Privacy and Security Notice | Contact Us

Last Updated on Monday, October 22, 2007
URL: http://cfpub.epa.gov