Main Title Volumetric leak detection in large underground storage tanks /
Author Starr, James W.; Wise, R. F.; Maresca., J. W.
CORP Author Vista Research, Inc., Mountain View, CA. ;CDM Federal Programs Corp., Fairfax, VA.;Environmental Protection Agency, Cincinnati, OH. Risk Reduction Engineering Lab.
Publisher U.S. Environmental Protection Agency, Office of Research and Development,
Place Published Washington, D.C.
Year Published 1991
Report Number EPA 600/2-91-044a; 68-03-3409; EPA-68-03-3409
Stock Number PB91-227942
OCLC Number 24842528
Subjects Underground storage; Storage tanks; Leakage; Volumetric analysis; Land pollution abatement; Performance standards; Pollution regulations; Crude oil; Materials tests; Standards compliance; Temperature; Petroleum products
Subject Added Ent Hazardous wastes.; Leak detection.; Underground storage.; Waste disposal in the ground.
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=200095PW.txt
Holdings
Library   Call Number Additional Info Location Date Modified
EICD EPA/600/2-91/044a IN STORAGE/UNAVAILABLE IN STORAGE/UNAVAILABLE 01/10/1992
EJAD EPA 600/2-91-044a HWTIC Region 3 Library/Philadelphia, PA 01/01/1988
EJBD ARCHIVE EPA 600/2-91-044a Headquarters Library/Washington,DC 03/17/2009
EJBD EPA 600/2-91-044a c.1-2 Headquarters Library/Washington,DC 12/30/2013
ELBD EPA/600/2-91/044a AWBERC Library/Cincinnati,OH 02/28/1997
EMBD EPA/600/2-91/044A GWERD Library/Ada,OK 12/24/1992
ENAD EPA/600/2-91/044a Region 7 IRC Library/Kansas City,KS 10/06/2000
EOAD EPA 600/2-91-044a Region 8 Technical Library/Denver,CO 02/22/2011
EOBD EPA/600/2-91/044a NEIC Library/Denver,CO 01/14/2000
ERAD EPA 600/2-91-044a Region 9 Library/San Francisco,CA 10/09/2012
ESAD EPA 600-2-91-044A Region 10 Library/Seattle,WA 03/23/2010
NTIS PB91-227942 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation xiii, 79 p. : ill. ; 28 cm.
Abstract A set of experiments was conducted to determine whether volumetric leak detection system presently used to test underground storage tanks (USTs) up to 38,000 L (10,000 gal) in capacity could meet EPA's regulatory standards for tank tightness and automatic tank gauging systems when used to test tanks up to 190,000 L (50,000 gal) in capacity. The experiments, conducted on two partially filled 190,000-L (50,000-gal) USTs at Griffiss Air Force Base in upstate New York during late August 1990, showed that a system's performance in large tanks depends primarily on the accuracy of the temperature compensation, which is inversely proportional to the volume of product in the tank. Errors in temperature compensation that were negligible in tests in small tanks were important in large tanks. The experiments further suggest that a multiple-test strategy is also required.
Notes "EPA/600/2-91/044a." "EPA contract no.: 68-03-3409." "August 1991." "EPA Project Officer: Robert W. Hillger." Includes bibliographical references.
Supplementary Notes Portions of this document are not fully legible. Prepared in cooperation with CDM Federal Programs Corp., Fairfax, VA. Sponsored by Environmental Protection Agency, Cincinnati, OH. Risk Reduction Engineering Lab.
Access Notes Also available on the Internet.
Author Added Ent
Wise, Richard F.;
Maresca, J. W.;
Hillger, Robert W.
Corporate Au Added Ent United States. Environmental Protection Agency. Office of Research and Development.; Risk Reduction Engineering Laboratory (U.S.); Vista Research, Inc.
PUB Date Free Form 1991
NTIS Prices PC A09/MF A02
BIB Level m
OCLC Time Stamp 20121004183946
Cataloging Source OCLC/T
Language eng
SUDOCS Number EP 1.23/2:600/2-91/044 A
Origin OCLC
Type CAT
OCLC Rec Leader 01564cam 2200421Ka 45020


Local Navigation


Jump to main content.