Main Title Arsenic removal from drinking water by ion exchange U.S. EPA Demonstration Project at Fruitland, ID : six-month evaluation report / [electronic resource] :
Author Wang, Lili.; Wang, L.; Chen, A. S. C.; Tong, N.; Coonfare, C. T.
CORP Author Battelle, Columbus, OH.;National Risk Management Research Lab., Cincinnati, OH. Water Supply and Water Resources Div.
Publisher National Risk Management Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency,
Place Published Cincinnati, Ohio
Year Published 2007
Report Number EPA/600/R-07/017
Stock Number PB2007-107916
OCLC Number 700943343
Subjects Arsenic; Drinking water; Chemical removal; Water treatment processes; Ion exchange; Water treatment plants; Water purification; Water wells; Sediments; Demonstration projects; Peerformance evaluation; U.S. EPA; Fruitland(Idaho)
Subject Added Ent Water--Purification--Arsenic removal--Idaho--Fruitland.; Ion exchange.
Internet Access
Description Access URL
Abstract http://www.epa.gov/nrmrl/pubs/600r07017/600r07017.htm
http://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=P1008AY6.txt
Holdings
Library   Call Number Additional Info Location Date Modified
EJBD POD Internet only Headquarters Library/Washington,DC 02/15/2011
NTIS PB2007-107916 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 10/08/2007
Collation 1 online resource ([81] p.) : ill., charts, digital, PDF file.
Abstract This report documents the activities performed during and the results obtained from the first six months of the performance evaluation of a Kinetico ion exchange (IX) system to remove arsenic (As) and nitrate from source water at the City of Fruitland in Idaho. The 250-gal/min (gpm) IX system consisted of a bank of five sediment filters and two 48-inch-diameter by 72-inch-tall pressure vessels configured in parallel. Each resin vessel contained 50 feet of a strong base anionic exchange resin, i.e., A300E manufactured by Purolite. The system installation first began in March 2004; however, the commencement of the system operation was repeatedly delayed until June 2005 due to a series of problems encountered. The problems started with excessive sediment production from the original supply well, followed by the failure of a replacement well to pass bacterial testing even after repeated sanitation efforts. The problems were further compounded by the need to replace the resin that was erroneously installed in the resin vessels and a broken well pump that was salvaged from the original supply well into the replacement well.
Notes "Contract No. 68-C-00-185,Task Order No. 0019." Title from title screen (viewed Nov. 5, 2010). "April 2007." "EPA/600/R-07/017." Includes bibliographical references (p. 59-60).
Supplementary Notes Sponsored by National Risk Management Research Lab., Cincinnati, OH. Water Supply and Water Resources Div.
Availability Notes Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
Access Notes Mode of access: World Wide Web.; System requirements: Adobe Acrobat Reader.
Author Added Ent
Coonfare, Chris T.;
Tong, Ning.;
Chen, Abraham S. C.,
Corporate Au Added Ent Battelle Memorial Institute.; National Risk Management Research Laboratory (U.S.). Office of Research and Development.
PUB Date Free Form 2007
Category Codes 68D; 50B; 99B
NTIS Prices PC A06
BIB Level m
Medium electronic resource
Control Number 019102130
OCLC Time Stamp 20110207122346
Cataloging Source OCLC/T
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01779nam 2200421Ia 45020