Main Title Reverse osmosis treatment to remove inorganic contaminants from drinking water {microform} /
Author Huxstep, Martin R.; Sorg, T. J.; Love, Jr, O. T.
CORP Author Municipal Environmental Research Lab., Cincinnati, OH.
Publisher U.S. Environmental Protection Agency, Water Engineering Research Laboratory,
Place Published Cincinnati OH :
Year Published 1984
Report Number EPA/600/D-84/198
Stock Number PB84-223528
OCLC Number 48180317
Subjects Water treatment; Inorganic compounds; Membranes; Industrial waste treatment; Water pollution control; Field tests; Potable water; Organic compounds; Ground water; Concentration(Composition); Performance evaluation; Water quality; Polymeric films; Composite materials; Reverse osmosis; Volatile organic compounds
Subject Added Ent Reverse osmosis; Drinking water--Contamination
Holdings
Library   Call Number Additional Info Location Date Modified
ERBD PB84-223528 NERL/ESD-LV Library/Las Vegas,NV 10/19/2001
NTIS PB84-223528 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation 24 p. ; 28 cm.
Abstract Because of the versatility of reverse osmosis for removing a wide range of contaminants, U.S. EPA (Drinking Water Research Division) has been conducting laboratory and field studies to determine its effectiveness on specific inorganic and organic contaminants of concern to the water supply industry. Laboratory and field studies for the removal of specific inorganic contaminants have shown that most of the contaminants listed in the EPA drinking water regulations are highly rejected (greater than 90%) while a few contaminants, such as fluoride, nitrate, and arsenic III, are only moderately rejected. Also, tests with different membranes showed only minor differences in removals. Laboratory studies using cellulose and nylon amide membranes have shown less than 25% rejection of volatile organic compounds. A thin film composite membrane, on the other hand, looked very encouraging in short duration (less than 4 hours) tests for removing VOCs. However, when the thin film composite membrane was exposed to contaminated ground water for a longer term, certain VOCs, primarily unsaturated and aeromatic compounds, permeated the membranes within 12 to 16 hours. Thus, the future for RO in controlling VOCs is uncertain.
Notes Caption title. "July 1984." "EPA/600/2-87/109." Microfiche.
Author Added Ent
Sorg, Thomas J.
Corporate Au Added Ent Water Engineering Research Laboratory.
PUB Date Free Form {1984}
NTIS Prices PC A02/MF A01
BIB Level m
OCLC Time Stamp 20011019132829
Cataloging Source OCLC/T
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01071nam 2200289Ka 45020


Local Navigation


Jump to main content.