Main Title Interlaboratory Study of Cellular Fluorescence Intensity Measurements with Fluorescein-Labeled Microbead Standards.
Author Vogt, R. F.; Cross, G. D.; Phillips, D. L.; Henderson, L. O.; Hannon., W. H.;
CORP Author NSI Technology Services Corp., Corvallis, OR. Environmental Research Lab. ;Centers for Disease Control, Atlanta, GA.
Publisher c1991
Year Published 1991
Report Number EPA/600/J-92/096;
Stock Number PB92-153899
Subjects Interlaboratory comparisons; Environmental monitoring; Data processing; Research and development; Sampling; Case studies; Quality assurance; Error analysis; Quality control; Statistical analysis; Water pollution sampling; Reprints; Watershed Manipulation Project
Holdings
Library   Call Number Additional Info Location Date Modified
NTIS PB92-153899 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 08/28/1992
Collation 13p
Abstract Assessing and achieving interlaboratory comparability is a major quality assurance challenge for large interdisciplinary, multi-institutional, environmental research projects. Eight laboratories routinely measure chemical constituents of various field and laboratory derived solution samples as part of the US EPA's Watershed Manipulation Project. A quarterly interlaboratory comparison study has been designed by EPA quality assurance personnel in Corvallis, OR (USA) to assess: (1) intralaboratory precision and accuracy, (2) interlaboratory precision, and (3) trends through time. Synthetic solution samples are prepared quarterly and sent via overnight express to participating laboratories. For each analyte, laboratories are requested to perform analyses in triplicate with each replicate measured under different calibrations; precision calculated from resulting data therefore includes a component of among-batch variability. Relative bias is calculated as the percent difference between a laboratory's mean and the median of the laboratories (the supplying laboratory's value being treated equally to the other laboratories). Overall precision is expressed as the coefficient of variation using laboratory means. An ANOVA approach is also used to calculate significant differences among laboratories. Data interpretation and results from four quarterly evaluations will be presented.
Supplementary Notes Pub. in Cytometry, v12 p525-536 1991. Prepared in cooperation with Centers for Disease Control, Atlanta, GA.
NTIS Title Notes Journal article.
Title Annotations Reprint: Interlaboratory Study of Cellular Fluorescence Intensity Measurements with Fluorescein-Labeled Microbead Standards.