| Main Title |
Environmental Technology Verification Program Environmental and Sustainable Technology Evaluations Report: Industrial Test Systems, Inc. Lead Paint Check Qualitative Spot Test Kit for Lead in Paint. |
| Author |
S. Buehler;
D. Rhoda;
J. Enriquesz;
E. Hartzell
|
| CORP Author |
Environmental Protection Agency, Washington, DC. Office of Research and Development. |
| Year Published |
2010 |
| Report Number |
EPA-W-09-024 |
| Stock Number |
PB2011-111507 |
| Subjects |
Lead based paints;
Lead (Metal);
Test design;
Audits;
Performance evaluation;
Figures;
Tables (Data);
Test procedures;
Quality assurance;
Verification tests;
Quality control;
Statistical methods;
LeadPaintCheck;
Qualitative spot test kit
|
| Holdings |
| Library |
|
Call Number |
Additional Info |
Location |
Date Modified |
| NTIS |
|
PB2011-111507 |
Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. |
NTIS |
03/09/2012 |
|
| Collation |
79p |
| Abstract |
This report provides results for the verification testing of LeadPaintCheck test kit for lead-based paint by Industrial Test Systems, Inc. The following is a description of the LeadPaintCheck test kit, based on information provided by the vendor. The information provided below was not verified in this test. LeadPaintCheck is a semi-quantitative test kit that can detect the presence or absence of lead in paint. To evaluate a sample, a half-inch circle paint sample is collected, the paint sample is cut up in smaller pieces, and then it is homogenized in the ACID-1 acid solution. Lead in the Homogenized Paint (HP) sample is solubilized as Pb+2 by the acid. The HP sample is then diluted 1/500 (100 microliters (Yl) per 50 milliliters (mL) of water). The procedure for measurement of lead in the diluted sample uses 4 mL of the HP extract, which are added to the built-in photocell of the eXactR LEADQuick. Photometer. The sample is zeroed, two drops of Pb-2 Buffer are added to make the solution mildly alkali (pH 9-10), and an eXactR Strip Pb-3 is then dipped in the sample for 20 seconds with gentle motion. The PB-3 strip simultaneously adds a porphyrin colorimetric indicator and mixes the solution. After one minute, in which time the porphyrin and Pb+2 forms a colorimetric complex, the eXactR LEADQuick. Photometer measures the optical density (color) as an absorbance number (abs). The 'SCabs' O value will be dependent on the amount of lead that is present: the higher the abs value, the higher the lead concentration in the sample. |
| Availability Notes |
Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5301 Shawnee Road, Alexandria, VA, 22312, USA. |
| PUB Date Free Form |
Dec 2010 |
| Category Codes |
68C; 99A; 71N |
| NTIS Prices |
PC A06 |
| Document Type |
NT |
| Control Number |
128500290 |
| Cataloging Source |
NTIS/MT |
| Origin |
NTIS |
| Type |
CAT |