| Main Title |
A summary of the 1984 EPA national performance audit program on source measurements / |
| Author |
Streib, E. W.;
Logan, T. J.;
Midgett, M. R.
|
| CORP Author |
Environmental Monitoring Systems Lab., Research Triangle Park, NC. Quality Assurance Div. |
| Publisher |
Environmental Monitoring Systems Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, |
| Place Published |
Research Triangle Park, N.C. |
| Year Published |
1986 |
| Report Number |
EPA/600/4-86/005 |
| Stock Number |
PB86-176401 |
| OCLC Number |
13808157 |
| Subjects |
Auditing;
Quality assurance;
Gas analysis;
Chemical analysis;
Sampling;
Combustion products;
Industrial wastes;
Air pollution detection;
National performance audit program
|
| Subject Added Ent |
Air--Pollution--Measurement.;
Environmental monitoring--United States.
|
| Internet Access |
|
| Holdings |
| Library |
|
Call Number |
Additional Info |
Location |
Date Modified |
| EIAD |
|
EPA/600/4-86/005 |
|
Region 2 Library/New York,NY |
12/03/2004 |
| EJAD |
|
EPA 600/4-86-005 |
|
Region 3 Library/Philadelphia, PA |
02/16/1996 |
| EJBD |
ARCHIVE |
EPA 600/4-86/005 |
|
Headquarters Library/Washington,DC |
04/10/2009 |
| EJBD |
|
EPA 600/4-86/005 |
|
Headquarters Library/Washington,DC |
02/24/2009 |
| EKAM |
|
EPA/600/4-86/005 |
|
Region 4 Library/Atlanta,GA |
07/08/1994 |
| EKBD |
|
EPA-600/4-86-005 |
|
Research Triangle Park Library/RTP, NC |
02/22/2011 |
| EOAD |
|
EPA 600/4-86-005 |
|
Region 8 Technical Library/Denver,CO |
03/21/2011 |
| ESAD |
|
EPA 600-4-86-005 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
| NTIS |
|
PB86-176401 |
Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. |
NTIS |
01/01/1988 |
|
| Collation |
viii, 34 p. |
| Abstract |
In 1984, the Quality Assurance Division conducted the National Audits for Stationary Source Test Methods. The audit materials consisted of: a calibrated orifice for Method 5 (DGM only), five simulated liquid samples each for Method 6 (SO2) and Method 7 (NOx), two coal samples for Method 19A, and a disposable gas cylinder for Method 3 (Orsat analyzer). Participating laboratories sent their data to the Source Branch and in return received a written report comparing their results to EPA's. In the Method 5 audit, the mean value for all participants differed by 3.1% from the expected (EPA) value. For the Method 6 audit, the average mean differed by 3.8% from the expected value, and in the Method 7 audit the average mean differed by 3.2%. In the two coal audits, the parameters measured were sulfur, moisture, ash, and Btu content. On the average for the sulfur analysis, 82% of the participants measured within 10% of the expected value; for Btu, 97% of the participants measured within 10% of the expected value. In the Method 3 audit, each parameter had only one concentration. The mean for CO2 was 1.5% from the expected value. The mean for 02 was 2.1%. |
| Notes |
"February 1986"--Cover. "EPA/600/4-86/005." |
| Supplementary Notes |
See also PB85-165025. |
| Access Notes |
Also available online. Location last verified: 1/7/2011. |
| Author Added Ent |
|
| Corporate Au Added Ent |
Environmental Monitoring Systems Laboratory (Research Triangle Park, N.C.) |
| PUB Date Free Form |
1986 |
| NTIS Prices |
PC A03/MF A01 |
| BIB Level |
m |
| OCLC Time Stamp |
20110309150229 |
| Cataloging Source |
OCLC/T |
| Language |
eng |
| Origin |
OCLC |
| Type |
CAT |
| OCLC Rec Leader |
01070cam 2200289Ka 45020 |