OLS : Record

RECORD NUMBER: 45 OF 1679

Main Title Air emissions from combustion of solvent refined coal /
Author Budden, Kenneth G.; Patel, Subhash S.
CORP Author Hittman Associates, Inc., Columbia, MD.;Industrial Environmental Research Lab., Research Triangle Park, NC.
Publisher U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor,
Place Published Research Triangle Park, NC Springfield, Va.
Year Published 1979
Report Number EPA-600/7-79-004; HIT/C165/860-78-733D2; EPA-68-02-2162
Stock Number PB-290 946
OCLC Number 08349833
Subjects Air pollution; Gas analysis; Flue gases; Electric power plants; Combustion products; Industrial wastes; Nitrogen oxides; Sulfur dioxide; Particles; Chemical analysis; Sampling; Comparison; Organic compounds; Inorganic compounds; Gas chromatography; Infrared spectroscopy; Air pollution; Coal; Solvent-refined coal
Subject Added Ent Coal--Combustion--Environmental aspects.; Combustion--Measurement.; Flue gases--Measurement.
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=9101E2K1.txt
Holdings
Library   Call Number Additional Info Location Date Modified
EJBD ARCHIVE EPA 600-7-79-004 Headquarters Library/Washington,DC 07/03/2013
EKAM 600/7-79/004 Region 4 Library/Atlanta,GA 08/19/1994
EKBD EPA-600/7-79-004 Research Triangle Park Library/RTP, NC 12/12/2003
EOAD EPA 600/7-79-004 Region 8 Technical Library/Denver,CO 04/25/2011
ESAD EPA 600-7-79-004 Region 10 Library/Seattle,WA 03/23/2010
NTIS PB-290 946 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 06/23/1988
Collation vii, 38 p. : ill. ; 28 cm.
Abstract The report gives details of a Solvent Refined Coal (SRC) combustion test at Georgia Power Company's Plant Mitchell, March, May, and June 1977. Flue gas samples were collected for modified EPA Level 1 analysis; analytical results are reported. Air emissions from the combustion of coal and SRC are compared for various organic and inorganic constituents, and SO2 and NOx. The impact of the air emissions from the combustion of SRC is assessed by comparison with EPA's Multimedia Environmental Goals and existing New Source Performance Standards. Air quality emissions test data indicated that SRC SO2 and NOx emissions were 1.06 and 0.43 lb/million Btu, respectively; or about 12 and 39% under the existing NSPS of 1.2 lb/million Btu for SOx and 0.7 lb/million Btu for NOx. If the SO2 standard is reduced, SRC derived from high sulfur coal may not meet the new standard. The low NOx emissions may be a result of the abnormally high excess air that was used during the test: additional testing at normal conditions is required. Particulate emissions can probably be controlled well below the EPA standard of 0.1 lb/million Btu by installing a modern ESP, with a particulate collection efficiency of about 95%.
Notes "Hittman Associates, Inc." "January 1979." Includes bibliographical references (p. 37). "Contract no. 68-02-2162, program element no. EHE623A."
Access Notes Also available via the World Wide Web
Author Added Ent
Patel, Subhash S.
Corporate Au Added Ent Industrial Environmental Research Laboratory (Research Triangle Park, N.C.); Hittman Associates.
Title Ser Add Ent Research reporting series. Interagency energy-environment research and development ; EPA-600/7-79-004.
NTIS Title Notes Final rept. Mar 77-Sep 78.
PUB Date Free Form 1979
Series Title Untraced Interagency energy/environment R & D program report ; EPA-600/7-79-004
Category Codes 7D; 68A; 97R
NTIS Prices PC A03/MF A01
Primary Description 600/13
BIB Level m
Control Number 323756306
OCLC Time Stamp 20130628091309
Cataloging Source OCLC/T
Language eng
SUDOCS Number EP 1.23/8:600/7-79-004
Origin OCLC
Type MERGE
OCLC Rec Leader 01675cam 2200373Ia 45020