| Main Title |
Method 1631 : mercury in water by oxidation, purge and trap, and cold vapor atomic fluorescence spectrometry. |
| CORP Author |
DynCorp - EENSP, Alexandria, VA. Environmental Programs Div.;Environmental Protection Agency, Washington, DC. Engineering and Analysis Div. |
| Publisher |
U.S. Environmental Protection Agency, Office of Water, |
| Place Published |
{Washington, D.C.} : |
| Year Published |
1996 |
| Report Number |
EPA 821-R-96-001;68-01-0337; EPA-68-C3-0337 |
| Stock Number |
PB96-193214 |
| OCLC Number |
36168791 |
| Subjects |
Water pollution sampling;
Quantitative chemical analysis;
Test methods;
Mercury(Metal);
Oxidation;
Desorption;
Fluorescence spectroscopy;
Atomic spectroscopy;
Analytical methods;
Laboratory procedures;
Quality control;
Water pollution detection;
Water pollution stanards;
Water analysis;
Ground water;
Surface waters;
EPA Method 1631;
Detection levels;
Purge and trap;
Cold-vapor atomic fluorescence detection;
Filtered water;
Unfiltered water
|
| Subject Added Ent |
Mercury--Analysis;
Water--Analysis;
Trace elements in water--Measurement;
Fluorescence spectrometry
|
| Internet Access |
|
| Holdings |
| Library |
|
Call Number |
Additional Info |
Location |
Date Modified |
| EIAD |
|
EPA 821-R-96-001 |
|
Region 2 Library/New York,NY |
03/10/2006 |
| EICR |
|
EPA-821-R-96-001 |
IN STORAGE/UNAVAILABLE |
IN STORAGE/UNAVAILABLE |
01/17/1997 |
| ERBD |
|
EPA/821/R-96/001 |
|
NERL/ESD-LV Library/Las Vegas,NV |
03/14/1997 |
| NTIS |
|
PB96-193214 |
Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. |
NTIS |
01/01/1988 |
|
| Collation |
iv, 33 p. : ill. ; 28 cm. |
| Abstract |
The method is for determination of total mercury (Hg) in filtered and unfiltered water by oxidation, purge and trap, desorption, and cold-vapor atomic fluorescence detection. The method is designed for measurement of total Hg in the range of 0.2-100 ng/L and may be extended to higher levels by selection of a smaller sample size. The method includes suggestions for improvements in facilities and analytical techniques that should maximize the ability of the laboratory to make reliable trace metals determinations and minimize contamination. |
| Notes |
"January 1996, Draft"--Cover. "EPA 821-R-96-001"--Cover. Includes bibliographical references. |
| Supplementary Notes |
See also PB95-252433. Sponsored by Environmental Protection Agency, Washington, DC. Engineering and Analysis Div. |
| Corporate Au Added Ent |
United States. Environmental Protection Agency. Office of Water. |
| Alternate Title |
Mercury in water by oxidation, purge and trap, and cold vapor atomic fluorescence spectrometry |
| PUB Date Free Form |
1996. |
| NTIS Prices |
PC A04/MF A01 |
| BIB Level |
m |
| OCLC Time Stamp |
20060308113150 |
| Cataloging Source |
OCLC/T |
| Language |
eng |
| Origin |
OCLC |
| Type |
MERGE |
| OCLC Rec Leader |
01038cam 2200265Ia 45170 |