OLS : Record

RECORD NUMBER: 21 OF 160

Main Title Biological treatment of combined sewer overflow at Kenosha, Wisconsin.
CORP Author Kenosha, Wis.;National Environmental Research Center, Cincinnati, Ohio.;Envirex, Inc., Milwaukee, Wis.;Alvord, Burdick and Howson, Chicago, Ill.
Publisher National Environmental Research Center, Office of Research and Development, U.S. Environmental Protection Agency,
Place Published Cincinnati, Ohio,
Year Published 1975
Report Number EPA-670/2-75-019; EPA-ROAP-21-ASY; EPA-11023-EKC
Stock Number PB-242 126
OCLC Number 01416584
Subjects Sewage treatment; Combined sewers; Overflows; Activated sludge process; Design; Construction; Performance evaluation; Surface water runoff; Automatic control equipment; Stabilization; Flocculating; Pumping; Settling; Clarification; Feasibility; Operating costs; Wisconsin; Kenosha(Wisconsin)
Subject Added Ent Combined sewers--Wisconsin--Kenosha.; Sewage--Purification--Biological treatment.; Combined sewers.; Sewage--Purification--Biological treatment.; Wisconsin--Kenosha.
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPURL.cgi?Dockey=9100TPA2.txt
Holdings
Library   Call Number Additional Info Location Date Modified
EIAD EPA-670/2-75-019 Region 2 Library/New York,NY 10/24/2003
EJAD EPA 670/2-75-019 Region 3 Library/Philadelphia, PA 08/30/1996
EJBD ARCHIVE EPA 670-2-75-019 Headquarters Library/Washington,DC 01/23/2012
EJBD EPA 670-2-75-019 c.1&2 Headquarters Library/Washington,DC 05/17/2013
EKAM TD745.B55 Region 4 Library/Atlanta,GA 10/23/1998
ELBD EPA-670/2-75-019 AWBERC Library/Cincinnati,OH 01/02/1998
EOBD EPA 670-2-75-019 NEIC Library/Denver,CO 08/27/1999
NTIS PB-242 126 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation xi, 247 p. ill. 27 cm.
Abstract The report describes the design, construction, operation and two-year evaluation of a biological process used for the treatment of potential combined sewer overflow. A 75,700 cu m/day (20 mgd) modified contact stabilization process was constructed on the grounds of an existing 87,055 cu m/day (23 mgd) conventional activated sludge plant at a total cost of 1.1 million dollars. The demonstration system consisted of pumping facilities, the conversion of an unused flocculation basin into a grit basin, construction of a contact tank and stabilization tank, installation of a final clarifier and all associated yard piping and automatic control equipment. The demonstration system's raw sewage pump and clarifier were used by the dry weather plant when the demonstration system was not in use.
Notes "Project No. 11023 EKC; Program element no.1BB034." Bibliography: p. 113-115.
Supplementary Notes Prepared in cooperation with Envirex, Inc., Milwaukee, Wis., and Alvord, Burdick and Howson, Chicago, Ill.
Author Added Ent
Agnew, Robert W.
Corporate Au Added Ent United States. Environmental Protection Agency. Office of Research and Development.; United States. National Environmental Research Center (Cincinnati, Ohio)
Title Ser Add Ent Research reporting series. Environmental protection technology ; EPA-670/2-75-019.
PUB Date Free Form 1975
Series Title Untraced Environmental protection technology series, EPA-670/2-75-019
NTIS Prices PC A12/MF A01
BIB Level m
OCLC Time Stamp 20120118121302
Cataloging Source OCLC/T
Language eng
SUDOCS Number EP 1.23/2:670/2-75-019
Origin OCLC
Type MERGE
OCLC Rec Leader 01485cam 2200337I 45020