Main Title Simulation of DNAPL Distribution Resulting from Multiple Sources.
Author Fishman, M.; Guarnaccia, J.; Wood, L.; Enfield, C.;
CORP Author Dynamac Corp., Ada, OK. ;CIBA-GEIGY Corp., Toms River, NJ.;Robert S. Kerr Environmental Research Lab., Ada, OK.
Publisher 2000
Year Published 2000
Report Number EPA-68-C4-0031; EPA/600/A-01/103;
Stock Number PB2002-101511
Subjects Ground water; Contamination; Simulation models; Numerical simulators; Porous media; Fluid entrapment; Saturation hysteresis; Aquifers; Dense non aqueous phase liquid(DNAPL); NAPL
Holdings
Library   Call Number Additional Info Location Date Modified
NTIS PB2002-101511 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 10/23/2002
Collation 12p
Abstract A three-dimensional and three-phase (water, NAPL and gas) numerical simulator, called NAPL, was employed to study the interaction between DNAPL (PCE) plumes in a variably saturated porous media. Several model verification tests have been performed, including a series of 2-D laboratory experiments involving the migration of PCE through a variably saturated, homogeneous sand. A comparison of the experimental data to the model results illustrates the effect and importance of fluid entrapment and saturation hysteresis. The NAPL model was used to simulate a 3-D multi point PCE source release within a contained test cell at the Groundwater Remediation Field Laboratory (GRFL) in Dover, Delaware. In this experiment, the migration of PCE in the unsaturated and saturated zones, under various infiltration scenarios, was simulated. The modeling of multiple injection points in a homogeneous aquifer shows that the ultimate distribution of PCE depends on the injection points in a homogeneous aquifer shows that the ultimate distribution of PCE release rates, and the depth to the water table. In general, an intermittent, slow, injection rate caused narrow, deeply penetrating DNAPL plumes. On the other hand, higher injection rates resulted in a wider horizontal distribution and more interaction between neighboring plumes, thus creating non-symmetric distributions and an increase in the flow rate and the depth of penetration.
Supplementary Notes Prepared in cooperation with CIBA-GEIGY Corp., Toms River, NJ. Sponsored by Robert S. Kerr Environmental Research Lab., Ada, OK.
Availability Notes Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
Category Codes 62B; 68C; 68D
NTIS Prices PC A03/MF A01
Primary Description 600/15
Document Type NT
Control Number 028900060
Cataloging Source NTIS/MT
Origin NTIS
Type CAT


Local Navigation